(300-1400℃) CVD diamond cultivation equipment dedicated coaxial single laser focusing aiming fixed installation with display online industrial Infrared Temperature Sensor has precise coaxial center laser aiming function
(300-1400℃) CVD diamond cultivation equipment dedicated coaxial single laser focusing aiming fixed installation with display online industrial Infrared Temperature Sensor has precise coaxial center laser aiming function, LCD displays the current status, can easily align the measurement target and indicate the best measurement distance. Provide users with easy-to-use and highly reliable measurement methods. Especially suitable for medium frequency heating, high frequency heating, microwave heating, CVD diamond cultivation equipment, graphene powder separation equipment, and other environments where contact measurement is not possible. Laser indicates the measurement direction, standard focusing lens can focus and measure 2 mm. The smallest spot is the best measurement position. The solid and durable sensor head meets the IP65 (NEMA4) standard. LCD temperature display, on-site emissivity adjustment. 4-20mA and digital output are optional.
a. Laser indicates the measurement direction, standard focusing lens can focus and measure 2 mm.
b. The smallest spot is the best measurement position.
c. The solid and durable sensor head meets the IP65 (NEMA4) standard.
d. LCD temperature display, on-site emissivity adjustment.
e. 4-20mA and digital output are optional.
f. Aviation connector connection, easy installation.
Induction heating, microwave heating, graphene powder equipment, CVD diamond cultivation, printing, papermaking, lamination, drying, processed food, textiles, pharmaceuticals, metallurgy, kilns, flat glass, refractory materials, heating furnaces, laser welders.
If you are interested in our Infrared Temperature Sensor, please contact us for more information and quotes.
Contact number: 156 3719 8390
Email: shirley@cysitech.com
Contact person: shirley
WeChat: 18736046549
Product model | CY-CF1400AD(CVD) |
Storage temperature | -20-80℃ |
Temperature range | 300-1400℃ |
Ambient temperature | 0-60℃ |
Environmental grade | IP65 |
Cable length Standard | 3m |
Net weight | 400g (including cable weight) |
Main body size | Diameter 45mm Length 112-114mm |
Main body material | Stainless steel shell |
Response band | 1.6μm |
Optical resolution | 150:1 |
Response time | 5ms |
Focal length | Fine-tunable |
Light outlet | 20mm (suitable for observation window equipment with diameter ≥20mm) |
Laser lighting | 1. Lead touch lighting delay or constant lighting (because the laser has a life span, it is generally not recommended to be constant lighting); |
2. When the target temperature is greater than the lower limit temperature of the instrument, aiming is automatically turned on with delay, and the laser delay extinction time is adjustable. | |
System accuracy | ±1% |
Repeat accuracy | ±1℃ |
Temperature resolution | 1℃ |
Emissivity | 0.01-1.00 adjustable |